025-16 Series 039-16 Series 050-05 Series 050-16 Series 050-T25 Series 050-R25 Series 075-25 Series 075-40 Series 100-05 Series 100-16 Series 100-25 Series 100-40 Series 125-25 Series Double-Ended Sockets Interface Probes X Probe Socketless X39-25 Series X50-25 Series X50-40 Series X75-25 Series X75-40 Series IC Probe Series Tech Info

Application Notes
 
Drill Hole Specifications
Socket Series
Hole Specifications
Drill Size
Decimal
025-16 Series
.0205 / .0215 [.520 / .550]
#75
0.0210
039-16 Series
.0307 / .0317 [.078 / .810]
1/32"
.80 mm
0.0312
0.0315
050-16 Series
050-05 Series
.0368 / .0378 [.935 / .960]
#63
.95 mm
0.0370
0.0374
050-T25 Series
050-R25 Series
.0380 / .0390 [.970 / .099]
#62
#61
0.0380
0.0390
075-25 Series
075-40 Series
.0530 / .0550 [1.35 / 1.40]
1.35 mm
#54
0.0531
0.0550
100-05 Series
100-16 Series
100-25 Series
100-40 Series
.0670 / .0690 [1.70 / 1.75]
#51
1.75 mm
0.0670
0.0689
125-25 Series
.0940 / .0960 [2.39 / 2.44]
2.4 mm
#41
0.0945
0.0960
QA Technology Company, Inc.
Tel:  (603) 926-1193 - Fax: (603) 926-8701

QA Technology highly recommends that holes initially drilled in fixture plates be verified using pin gauge tools (PG Tools) due to the tolerances of purchased drill bits which can be undersized by as much as .0005” or more. The machine feed rate, RPM and material used, can also affect the hole size. Undersized holes will not pass go-no-go pin gauge testing. Undersized holes may create problems when inserting the sockets. Therefore, QA Technology strongly suggests the use of pin gauges for hole size verification before attempting socket installation during the assembly of the fixture.